A practical guide to laminated busbar design — how they are built, how to choose dielectrics, how current capacity works, and what to check before you release a drawing.
In a typical power-electronics build, the same power-electronics laminated busbar carries the DC link between the buffer capacitors and the IGBT or SiC power modules — forward and return paths on adjacent planes, with terminals lined up exactly where the modules and capacitors sit. Electrically it is a multilayer circuit; mechanically it is a single rigid part that installs in one motion.
Because the conductor geometry is tooled rather than hand-routed, the same assembly ships consistent unit to unit: the same loop area, the same terminal positions, the same insulation margins. That repeatability is what makes the part viable at production volumes — the geometry behind it is detailed in our low-inductance busbar design article.
We build from C11000 copper as standard; aluminum conductors are available on request when weight or raw-material cost drives the selection. The trade-offs are detailed in copper vs aluminum busbar conductors. Every lot passes in-house QC under our laminated busbar testing process — hipot, insulation resistance, dimensional, visual and continuity checks — with batch test records and CoC-style documentation supplied on request.
Layer count typically runs from one to six or more. Adjacent conductors are offset in the stack so every terminal stays reachable, and the dielectric covers the copper with a margin matched to the voltage class. After lamination, cut edges are sealed before terminals are welded or fastened, so the finished part can be handled like any other component.
| Material | Strengths | Watch-outs |
|---|---|---|
| PET (Mylar) | Low cost, good dielectric strength, thin for compact stacks | Lower continuous temperature limit than alternatives |
| Nomex | High temperature rating, excellent thermal stability | Higher cost, thicker per layer |
| Epoxy (DLF) | Rigid, self-extinguishing options, good mechanical strength | Less flexible stack-up, material handling during layup |
Three indices decide the choice beyond cost and thickness:
Above roughly 1000 V, flexible film alone is usually not enough. A rigid inter-layer board — commonly glass-reinforced polyester — is added between conductor sub-assemblies, with a rule of thumb of about 1 mm of rigid insulation per kV of maximum operating voltage. The related field-stress design and acceptance testing are covered in partial discharge in laminated busbars, and temperature-limited designs are covered in busbar thermal management.
| Copper cross-section | Approx. DC current (30 °C rise) |
|---|---|
| 10 × 3 mm | ~150 A |
| 20 × 3 mm | ~250 A |
| 30 × 5 mm | ~450 A |
| 40 × 5 mm | ~550 A |
| 50 × 5 mm | ~650 A |
| 60 × 6 mm | ~800 A |
| 80 × 6 mm | ~1000 A |
| 100 × 6 mm | ~1150 A |
Two limits govern the sizing, and they are easy to confuse. Temperature rise: resistive heating in the conductor must stay within the margin your enclosure allows — the 30 °C reference above assumes a 40 °C ambient and free-air mounting. Insulation class: the dielectric sets the ceiling — a 105 °C PET system cannot run at 130 °C no matter how large the copper is. Sizing runs both ways: first the cross-section for temperature rise, then the dielectric choice against the resulting steady-state temperature.
Doubling the copper area does not double the rating inside an enclosure — adjacent layers and neighboring parts heat each other, and the derating factors in our ampacity chart apply on top of these numbers.
Every switching circuit pays a voltage tax for its loop inductance. When a switch commutates from on to off, the loop current cannot stop instantly; it crashes into the now-open switch and creates a spike across the device. The spike follows V = L × di/dt — loop inductance multiplied by the rate of current change. The faster the switch, SiC devices in particular, the more expensive millihenry-scale loop inductance becomes.
Inductance is set by the magnetic flux between the forward and return paths, and flux is proportional to loop area. In a cable harness the positive and negative conductors sit centimeters apart and the loop area is large. In a laminated busbar they sit fractions of a millimeter apart as parallel planes — the geometry that naturally cancels flux. As a reference, for an equivalent 1 m run: a pair of round wires 1 mm apart carries roughly 0.4 mH of loop inductance; the same cross-section laminated as a stack lands near 50 nH, and with thin-film dielectrics under 0.2 mm the same loop can fall below 20 nH.
Two empirical scaling rules from reference design practice are worth memorizing:
The design consequence is a balancing act: minimize spacing while still meeting the required insulation level, minimize loop length while still leaving room for heat, and balance positive and negative plane overlap at every terminal. Terminal overlap — not the straight run of bar — usually dominates the final number. We cover the full rule set, including FEM-based iteration, in low-inductance busbar design: principles and layout rules.
Small geometry changes move the number a lot, so the practical workflow is simulation, not trial prototypes: model the busbar alone, replace the capacitors with a short-circuit block so current follows the lowest-impedance path, probe at the device terminals, and iterate on the highest-flux areas. A reference optimization loop runs from about 12 nH on a baseline bent-terminal layout to below 5 nH after flattening terminals and increasing plane overlap — roughly a 60% reduction, with the terminal overlap and the capacitor interface responsible for most of the gain.
A cut copper edge is where insulation failure usually starts. Two failure modes meet at the edge: tracking along the surface under voltage, and partial discharge inside any trapped air gap.
Edge sealing. The dielectric film is coated with an adhesive that activates during the heat-and-pressure lamination cycle. It bonds the film to the conductor and, critically, folds over the cut edge so that no bare edge and no air gap is left exposed. The seal has to hold across the full atmospheric range of the design — humidity cycling and, at altitude, low pressure, where the breakdown strength of any trapped air bubble falls sharply (air dielectric strength drops from roughly 3.1 kV/mm at sea level to about 2.0 kV/mm near 0.5 bar).
Creepage and clearance. Clearance is the air distance between two conductors; creepage is the surface distance along the insulation between free terminals. Requirements scale with voltage class and pollution severity, and IEC 60664-style tables are the usual starting reference. The film's CTI rating sets how much creepage you actually need — which is why we confirm voltage class and environment before recommending a dielectric system.
Partial discharge. Even a sealed stack can host micro-gaps, and air in a micro-gap ionizes under field stress. Per the IEC 60270 definition (clause 3.1), partial discharge is a localized discharge that only partially bridges the insulation — typically pulses shorter than 1 µs. Intermittent PD is harmless; continuous PD above 10 pC erodes insulation over years and can end in short circuit. We verify PD below 10 pC on finished parts, even at test voltages above the operating voltage. Full mechanism and test guidance: partial discharge in laminated busbars.
The required level of edge sealing and creepage scales with the environment, not just the voltage:
| Aspect | Industrial / traction | Automotive |
|---|---|---|
| Voltage range | 1000–6000 V | 400–800 V |
| Partial discharge | Critical — rigid inter-layer insulation mandatory | Typically not required below 800 V |
| Creepage / CTI | High creepage needs; good-CTI film required | CTI usually not critical |
| Design life | Up to 25 years | Under 5 years |
| Reference test voltage | Per PD and clearance design | Typically 2.5 kV AC / 3.7 kV DC |
Terminals are where current enters and leaves the stack, and where most field problems originate. The standard options:
| Terminal type | Typical use | Watch-outs |
|---|---|---|
| M6 / M8 threaded studs | Bolted module and bus-to-bus joints | Torque control; spring or Belleville washers for cycling loads |
| Blade tabs | Connector insertion, service swaps | Tab contact area sets the joint rating |
| Welded lugs and welded tabs | Permanent high-current joints | Weld position must not open the commutation loop |
| Screw terminals | Low-current sense connections on hybrid stacks | Keep sense lines away from power edges |
| Fused links | Protected branches in distribution designs | Calibration and fault energy must be reviewed early |
Four connection techniques come up repeatedly in DFM review:
Joint contact resistance is kept low by tin plating the conductor, standard on our parts, which also protects against oxidation over the product life.
Beyond the items above, our DFM review typically turns up four additional things to confirm early: